PMA team reviewing TD-120 online oil-in-water monitoring data

Oil in Water Monitor for Continuous Hydrocarbon Detection

Detect oil and hydrocarbon changes continuously, create meaningful alarms and protect water, treatment processes and plant assets.

ONLINE HYDROCARBON MONITORING

A Monitor Built Around The Process Decision

An oil-in-water monitor continuously checks a flowing water sample for fluorescent hydrocarbons. It reveals short events and gradual changes that an occasional grab sample can miss.

A dependable installation combines the analyser, representative sampling point, sample transport, flow, pressure, temperature, water background, calibration and a clear response to every alarm.

When Continuous Monitoring Is The Right Choice

Start with the operational decision. These three common requirements determine where continuous monitoring adds the most value.

01 / EARLY WARNING

Catch Short-Lived Oil Events

See leaks, cross-contamination and treatment upsets between scheduled grab samples, then investigate before the event spreads.

02 / PROCESS CONTROL

Trend Treatment Performance

Follow oil carryover through separation and treatment stages and check whether an operational adjustment produced the intended result.

03 / PLANT RESPONSE

Turn Readings Into Action

Connect a trusted signal to alarms, trending and plant control so operators know when to investigate, isolate or verify a stream.

Choose The Monitoring Route

Continuous monitoring and portable analysis answer different questions. Select the route around measurement frequency, location and the hydrocarbon target.

TD-120 continuous oil-in-water monitor

CONTINUOUS ONLINE

TD-120 Oil-In-Water Monitor

Continuous UV fluorescence measurement with a remote flow cell, touchscreen, configurable alarms and outputs for plant integration.

TD-560 portable oil-in-water analyser

PORTABLE ANALYSIS

TD-550 And TD-560 Portable Analysers

Portable UV fluorescence analysis for field investigations, treatment checks, verification and measurements across several sampling points.

From Sample To Operator Action

The measurement chain is only useful when every stage supports a representative, repeatable result.

01

Deliver

Bring a representative flowing sample to the measurement cell within the agreed flow, pressure and temperature limits.

02

Excite

Ultraviolet light stimulates aromatic hydrocarbons in the water sample to produce fluorescence.

03

Measure

The optical response is converted through application calibration into a concentration or useful process trend.

04

Act

Display, trend and alarm the result so the operator has a defined response when the process changes.

Low ppb

Application-dependent detection capability

6,000 ppm

Published upper-range configuration

3 seconds

Default instrument response

4–20 mA

Plant output with optional HART

SPECIFICATION GUIDE

Specify The Complete Measurement

The best oil-in-water monitor is the one that produces a trusted signal and a clear operational response. PMA reviews the monitor together with the sampling and process requirement.

01

Target Oil

Identify crude oil, refined fuel, aromatic hydrocarbons or another defined target.

02

Measuring Range

Confirm normal background, alarm thresholds and maximum expected concentration.

03

Water Matrix

Review solids, turbidity, salinity, chemicals and background fluorescence.

04

Sample Path

Define the take-off point, transport time, conditioning, flow, pressure and temperature.

05

Calibration

Use representative standards or target oil and agree the reporting basis.

06

Outputs

Plan displays, data, alarms, fault handling and connection to plant control.

Where Oil-In-Water Monitoring Adds Value

Choose an application route for more specific sampling, alarm and product guidance.

PROCESS PROTECTION

Cooling Water And Heat Exchangers

Detect hydrocarbon changes that may indicate a leak or process crossover before contamination spreads.

TREATMENT CONTROL

Produced Water

Trend oil carryover through separation and treatment, investigate upsets and support discharge decisions.

WASTEWATER

Refinery And Petrochemical Streams

Monitor changes before treatment, reuse or discharge and protect downstream equipment from unexpected oil events.

Three Different Measurement Jobs

Oil in water, oil on water and laboratory reference analysis are related, but they are not interchangeable.

Oil In Water

Measures a response from hydrocarbons within a flowing water sample for trends, alarms and process decisions.

Oil On Water

Detects a floating surface film for gross spill warning. It does not provide the same in-stream measurement objective.

Laboratory Reference

Supports prescribed or accredited reporting. Online monitoring should be related to the site reference method where required.

Oil-In-Water Monitor Questions

Clear answers to the main questions raised during application review.

What Does An Oil-In-Water Monitor Measure?

It measures an optical response from fluorescent hydrocarbons in a flowing water sample and reports a calibrated concentration or trend. The response depends on the oil type, optical configuration, calibration and water matrix.

Monitor Or Analyser?

The terms are often used interchangeably. “Monitor” usually means continuous online measurement and alarms; “analyser” can also describe portable or laboratory-style sample measurement. “Oil in water analyzer” is the common US spelling.

Can One Calibration Be Used For Every Oil?

Not necessarily. Hydrocarbons can fluoresce differently, so representative calibration and an understood water background are important. Recheck the application when the oil or stream changes.

Does TD-120 Replace Compliance Testing?

Do not assume so. TD-120 supports operational monitoring, alarms and investigation. Any relationship to a prescribed laboratory method must be established for the application.

Continue Your Monitoring Research

Move directly to the product, application or measurement guide that matches your next decision.

Online Monitor Overview

Compare the online-monitoring route and how TD-120 fits.

UV Fluorescence

Understand the measurement principle, strengths and practical limits.

Portable Vs Online

Choose between grab-sample analysis and continuous monitoring.

TD-120 Product Page

Review the instrument features, ranges and installation details.

Specify The Right Oil-In-Water Monitor With PMA

Share the target hydrocarbon, expected range, water conditions, sample flow, temperature and pressure, alarm action and plant outputs.